A common 8 mm reference scale-factor magnitude is 7.87 mV/μm (200 mV/mil). Verify output polarity, linear range, DC gap voltage and the monitor input before replacement. Other tip sizes may use different scales. Probe tip diameter and thread must be verified on the assembly drawing; listed sizes are not freely combinable.
SENSOR SYSTEMS / ECS-3300
Eddy current shaft vibration & proximity probes
Review a complete probe, extension cable and driver assembly for radial vibration, eccentricity and axial thrust-position monitoring.
Specify this system ↗Steam turbines · centrifugal compressors · large motors
Define the conditions behind the measurement
Match the complete electrical length: probe integral cable plus extension cable. A 5 m or 9 m assembly is a configured system, not a freely extendable cable.
API 670 project requirements include more than a probe sensitivity. Request documented system qualification before using a configuration for protection or trip service.
Listed ranges and interfaces are inquiry options. Approved ratings, drawings and calibration data belong to the selected configuration.
Metal grade, thickness and curvature change the curve.
Request factory linearization for AISI 4140 / 42CrMo, aluminum 6061, stainless steel 304 / 316, copper or titanium. Confirm the representative target and calibration conditions in your quote.
| Decision | Eddy current displacement system | Standard inductive proximity switch |
|---|---|---|
| Measurement | Continuous distance or dynamic motion | Target present / absent |
| Output | Calibrated voltage, current or digital distance | Discrete ON / OFF |
| Specify | Range, resolution at bandwidth, target and calibration | Switching distance, hysteresis and switching frequency |
Analog inductive distance sensors also exist. Compare the actual measurement principle and performance, rather than the category name alone.
Before you approve the measuring system
Can the same calibration be used on steel and aluminum?
Do not assume so. Specify the material grade, thickness and curvature and agree the calibration curve for your target.
Can a replacement probe be mixed with an existing driver?
Only after the exact probe, electrical length, driver, target and output curve have been qualified together. Connector fit alone is insufficient.
What does a configuration quote include?
Request a matched probe, cable and conditioner, selected mounting accessories, calibration conditions, performance evidence and confirmed price and delivery.
ECS-3300 / CONFIGURATION REQUEST
Build the probe, cable and conditioner together.
Include a mounting adapter, armored cable or portable calibration fixture in the request below.